REQUEST A QUOTE or ASK A QUESTION ABOUT THIS PRODUCT
Available Options
  • Enhanced Accuracy - Code C
  • Foot Mount - Code F
  • Energy Calculation - Code E

MCRT 48000P Series Horsepower/kWh Meters

Model #48000P

These strain gage based Horsepower/kW-h Meters measure and output shaft power, energy (option), torque and speed in analog and digital form. Digital computation of power and energy is errorless. With 2X overload, they are available in ranges from 25 lbf-in to 4,000,000 lbf-in (power ranges from 5.95 to 76,160 hp). Both flange and shaft style configurations are offered.

Null, scaling and units of measure are stored in non-volatile memory. There are no noisy pots or switches. Fifty-one common units of measure are supported without requiring recalibration. Eleven user selectable Bessel filters avoid delay distortion and overshoot errors. These models incorporate new technology that hardens them to EMI generated by IGBT based adjustable speed drives.

Included software interfaces Windows-based PC’s and displays and plots real time data. Use it to select 5V or 10V analog outputs, filters, scaling, units of measure and/or to control measurements.

General Specifications

 

Code N Performance

Code C Performance

Nonlinearity (end point, % of full scale)

Power, Energy and Torque

±0.1

±0.05

Speed

±0.01

±0.01

Hysteresis (end point, % of full scale)

Power, Energy and Torque

±0.1

±0.05

Speed

±0.01

±0.01

Nonrepeatability (% full scale)

Power, Energy and Torque

±0.05±0.03

Speed

±0.005

±0.005

Combined Accuracy (% of full scale)

Power, Energy and Torque

±0.13

±0.08

Speed

±0.06

±0.06

Rotational Effect on Zero (% of full scale)

±0.05

±0.03

Temperature Effects (Power, Energy and Torque)

Zero (% of full scale/deg F.)

±0.003

±0.0015

Span (% of reading/deg F.)±0.003±0.0015
Compensated Range

+75 to +175 deg F

Minimum Usable Range

-25 to +185 deg F

Storage Range

-65 to +225 deg F

Analog Outputs, Auto-Scaled
Power, Energy and Torque

±10 or ±5 Volts dc, user selectable

Speed

+10 or +5 Volts dc, user selectable

Nominal Overrange (% of full scale)

50

Signal Filter Cutoff

0.1 to 200 Hz in eleven 1-2-5 steps, user selectable

System Resolution (% of full scale)

0.02 (14 bits with 50% overrange)

RS232 Communications Port

Outputs Power, Energy, Torque and Speed with units of measure. Inputs range selections, scaling, cal info and units of measure.

Supply Voltage

11 to 24 volts dc @ 150 mA, nominal