Rotating, Analog Torque Transducers

     ✓  Available Outputs:
        - mV/V strain gage  
    - 4-20 mA or 12±8 mA  
    - ±5 or ±10 volts dc  
     ✓  Choose from wide variety of configurations For selection assistance, call 1-800-632-7873
Title mV/V Output Low Range Transducers, 2XmV/V Output Torque Transducers - 2X, ShaftmV/V Output Torque Transducers - 2X, FlangedmV/V Output Low Range Transducers, 4XmV/V Output Torque Transducers - 4X, ShaftmV/V Output Torque Transducers - 4X, Flanged2-Wire Torque Transmitters, Shaft2-Wire Torque Transmitters, Flanged
Model 28000T28000T Series28000T Series 29000T 29000T Series 29000T Series 39000X Series 39000X Series
Description ShaftShaftFlangedShaftShaftFlangedShaftFlanged
Range (N-m) 3452,000452,0001.41226,000226,000226,000226,000
Range (lbf-in) 26.5524,000,537.0634,000,537.06312.482,000,268.5322,000,268.5322,000,268.5322,000,268.532
Mechanical Overload 200%200%200%400%400%400%400%400%
Accuracy ±0.1±0.1 & ±0.05±0.1 & ±0.05±0.1±0.1 & ±0.05±0.1 & ±0.05±0.1 & ±0.05±0.1 & ±0.05
Speed 25,00015,0008,00025,00015,00015,00015,0008,000
Output Signal mV/VmV/VmV/VmV/VmV/VmV/V4-20 mA or 12±8 mA4-20 mA or 12±8 mA
Overrange ext. amplifier dependentext. amplifier dependentext. amplifier dependentext. amplifier dependentext. amplifier dependentext. amplifier dependent125%125%
Compatible Display 701, 711, 721701, 711, 721701, 711, 721701, 711, 721701, 711, 721701, 711, 721706, 726, 766706, 726, 766
Specification Sheet B716B761B761B716B709B709B7300B7300
Title Low Capacity DC Operated Torque Transducers - 2XDC Operated Torque Transducers - 2X, ShaftDC Operated Torque Transducers - 2X, FlangedLow Capacity DC Operated Torque Transducers - 4XDC Operated Torque Transducers - 4X, ShaftDC Operated Torque Transducers - 4X, FlangedHigh Overload DC Operated Torque Transducers - 10X, ShaftHigh Overload DC Operated Torque Transducers - 10X, Flanged
Model 48000V48000V Series48000V Series49000V49000V Series49000V Series59000V Series59000V Series
Description ShaftShaftFlangedShaftShaftFlangedShaftFlanged
Range (N-m) 3452,000452,0002226,000226,00083,04083,000
Range (lbf-in) 26.5524,000,537.0634,000,537.06317.7012,000,268.5322,000,268.532734,965.924734,611.894
Mechanical Overload 200%200%200%400%400%400%1000%1000%
Accuracy ±0.1±0.1 & ±0.05±0.1 & ±0.05±0.1±0.1 & ±0.05±0.1 & ±0.05±0.1±0.1
Speed 25,00015,0008,00025,00015,0008,00015,0008,000
Output Signal ±10 Vdc, ±5 Vdc±10 Vdc, ±5 Vdc±10 Vdc, ±5 Vdc±10 Vdc, ±5 Vdc±10 Vdc, ±5 Vdc±10 Vdc, ±5 Vdc±10 Vdc, ±5 Vdc±10 Vdc, ±5 Vdc
Overrange 130%133%133%133%133%133%133%133%
Compatible Display 703, 723, 733703, 723, 733703, 723, 733703, 723, 733703, 723, 733703, 723, 733703, 723, 733703, 723, 733
Specification Sheet B7402B7401B7401B7402B7400B7400B7590B7590
Title Dual Range DC Operated Torque Transducers - ShaftDual Range DC Operated Torque Transducers - Flanged
Model 79000V Series79000V Series
Description ShaftFlanged
Range (N-m) 452,000452,000
Range (lbf-in) 4,000,537.0634,000,537.063
Mechanical Overload 200%200%
Accuracy ±0.1±0.1
Speed 15,0008,000
Output Signal ±10 Vdc, ±5 Vdc±10 Vdc, ±5 Vdc
Overrange 133%133%
Compatible Display 703, 723, 733703, 723, 733
Specification Sheet B7700B7700